99精品福利视频_久久香蕉国产线看观看av_黄色国产精品_亚洲电影第1页
您好,歡迎進入上海力敏實業有限公司網站!
一鍵分享網站到:
您現在的位置:首頁 >> 產品中心 >> >> >> B-1255VECTOR 生物素莧尾狀凝集素(ACL,ACA) BIOTIN-ACL

VECTOR 生物素莧尾狀凝集素(ACL,ACA) BIOTIN-ACL

  • 更新時間:  2023-07-24
  • 產品型號:  B-1255
  • 簡單描述
  • VECTOR 生物素莧尾狀凝集素(ACL,ACA) BIOTIN-ACL
    Biotinylated Amaranthus Caudatus Lectin (ACL, ACA)
    Detection of Glycoproteins using Lectins in Histochemistry,
    ELISA, and Western Blot Applications
詳細介紹

VECTOR 生物素莧尾狀凝集素(ACL,ACA) BIOTIN-ACL

The following protocols offer guidelines for assay development using lectin-based detection of glycoproteins
present in tissue sections, adsorbed onto microtiter plates, or transferred from electrophoretic
gels onto nitrocellulose or PVDF membranes.
Histochemistry:
1a. Staining procedure for paraffin sections: Deparaffinize and hydrate tissue sections through
xylenes or other clearing agents and graded alcohol series and rinse for 5 minutes in tap water.
If required, retrieve antigens using the Antigen Unmasking Solution (H-3300 or H-3301).
1b. Staining procedure for frozen sections: Air dry sections. Immediay before staining, fix
sections with acetone. Transfer slices to buffer. If endogenous enzyme activities are present,
inactivate using appropriate methods.
2. Perform Streptavidin/Biotin blocking if required following kit instructions (SP-2002). Do not
use SP-2001. Block non-specific binding by incubating section with Carbo-Free™ Blocking
Solution (Cat. No. SP-5040) for 30 minutes at room temperature. Blot excess blocking solution
from the sections.
3. Apply biotinylated lectin at approximay 2-20 μg/ml in PBS (10 mM sodium phosphate, 150
mM NaCl, pH 7.4) to the sections and incubate for 30 minutes at room temperature. Wash with
TPBS (PBS + 0.05% Tween™20).
4. Prepare VECTASTAIN®
® ABC (peroxidase, Cat. No. PK-6100) or VECTASTAIN® ABC-AP
(alkaline phosphatase, Cat. No. AK-5000) reagents according to the kit instructions. Apply to the
sections and incubate for 30 minutes at room temperature. Wash with TPBS.
5. Apply an appropriate precipitating substrate for the enzyme system used in step 4. For peroxidase,
ImmPACT™ DAB (Cat. No. SK-4105) is recommended; for alkaline phosphatase, Vector® Red
(Cat. No. SK-5100). Rinse in tap water.
6. Counterstain (optional), clear and mount. For galactose or GalNAc-specific lectins avoid mounting
in glycerol-based mounting media.
VECTOR 生物素莧尾狀凝集素(ACL,ACA) BIOTIN-ACL

ELISA:
1. Adsorb target protein to microtiter plate by placing 50-200 μl of approximay 3 μg/ml glycoprotein
solution into the desired wells. Some wells may be left untreated as negative controls. Incubate at
37 oC for 1 hour. Wash wells three times with TPBS (PBS + 0.05% Tween™20).
2. Block non-specific binding by filling each well to the brim with Carbo-Free™ Blocking Solution
(Cat. No. SP-5040) for 30 minutes at room temperature. Wash wells three times with TPBS.
3. Apply 50-200 μl of approximay 2-20 μg/ml biotinylated lectin in PBS to the wells and incubate
for 30 minutes at room temperature. Wash wells three times with TPBS.

4. Prepare VECTASTAIN®
® ABC (peroxidase, Cat. No. PK-6100) or VECTASTAIN® ABC-AP
(alkaline phosphatase, Cat. No. AK-5000) reagents according to the kit instructions. Apply to the
wells and incubate for 30 minutes at room temperature. Wash wells three times with TPBS.
5. Apply an appropriate non-precipitating substrate for the enzyme system used in step 4. For
peroxidase, ABTS (Cat. No. SK-4500) is recommended; for alkaline phophatase, pNPP (Cat. No.
SK-5900).
6. Quantify the colored reaction product by spectrophotometry.
Western Blot:
1. Perform electrophoresis and transfer proteins to a membrane according to standard procedures.
2. Block non-specific binding by incubating the membrane in Carbo-Free™ Blocking Solution (Cat.
No. SP-5040) for 30 minutes at room temperature. Use a sufficient volume to compley cover
the membrane.
3. Incubate membrane in PBS containing approximay 2-20 μg/ml biotinylated lectin for 30 minutes
at room temperature. Wash with TPBS (PBS +0.05% Tween™20).
4. Prepare VECTASTAIN®
® ABC (peroxidase, Cat. No. PK-6100) or VECTASTAIN® ABC-AP
(alkaline phosphatase, Cat. No. AK-5000) reagents according to the kit instructions. Incubate the
membrane in the reagent for 30 minutes at room temperature. Wash with TPBS.
5. Apply an appropriate substrate for the enzyme system used in step 4. For peroxidase, DuoLuX™
Chemiluminescent/Fluorescent Substrate for Peroxidase (Cat. No. SK-6604) or ImmPACT™ DAB
(Cat. No. SK-4105) are recommended; for alkaline phosphatase, Chemiluminescent/Fluorescent
Substrate for Alkaline Phosphatase (Cat. No. SK-6605) or BCIP/NBT (Cat. No. SK-5400) are
recommended.
Negative Controls
Negative controls should be run in parallel in each of the above described methodologies to validate
binding results. When applying lectins, one of the most appropriate negative controls is to preabsorb
the lectin with a concentration of a defined sugar, with which, the lectin has a known high affinity.
Vector Labs offers a series of sugars that are intended for such a purpose.
The lectin is diluted to a suitable working concentration in a solution containing approximay
200 mM to 500 mM of the sugar. This mixture is left to bind at room temperature for 30 to 60 min.
Following this absorption incubation, the mixture is substituted into the procedure in place of the unabsorbed
lectin and incubated under the same conditions. The subsequent detection procedure is followed
as for the test method. In most cases the vast majority of lectin binding to the tissue section (membrane
blot, etc.) will be eliminated. Some trace binding to the section (blot etc) may still be present under
these conditions and probably indicates presence of secondary or tertiary sugar preferences. These negative
control results should be compared with the test results to determine specificity of binding

 

上海力敏實業有限公司代理VECTOR產品,咨詢 詳細產品信息


留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7
友情鏈接: 等離子去膠機       電液伺服萬能材料試驗機       電液伺服液壓萬能試驗機       電子拉伸萬能試驗機       材料拉伸試驗機       金剛石鉆孔機       北斗定位器       控溫式遠紅外消煮爐       切膠儀       無塵紙       金屬液氮冷凍箱       傳力接頭       磁座鉆       LEM電壓傳感器       鋁儲罐      
99精品福利视频_久久香蕉国产线看观看av_黄色国产精品_亚洲电影第1页
主站蜘蛛池模板: 亚洲小视频在线观看| 欧美精品一区在线发布| 亚洲在线1234| 久久综合伊人77777| 国产精品乱人伦一区二区 | 国产精品一区二区久久国产| 91久久久一线二线三线品牌| 欧美在线综合| 国产精品美女久久久免费| 日韩午夜激情av| 男女激情久久| 亚洲激情av| 欧美精品免费观看二区| 亚洲国产欧美一区二区三区丁香婷| 久久久国产午夜精品| 国产日韩一区| 久久精品视频导航| 国产亚洲精品高潮| 欧美在线一级视频| 国产色产综合产在线视频| 欧美一级专区| 国产亚洲成人一区| 久久久久国产精品午夜一区| 黑人操亚洲美女惩罚| 美女黄色成人网| 最新日韩中文字幕| 欧美日韩成人综合在线一区二区 | 美玉足脚交一区二区三区图片| 国产一区二区三区在线播放免费观看| 欧美一级免费视频| 怡红院av一区二区三区| 蜜臀久久99精品久久久画质超高清 | 国产一区二区三区在线观看视频 | 国内成+人亚洲+欧美+综合在线| 久久av一区二区三区| 狠狠v欧美v日韩v亚洲ⅴ| 美日韩精品免费| 久久福利影视| 久久―日本道色综合久久| 欧美久久电影| 亚洲主播在线|